CWDM vs DWDM: Expanding Capacity Without New Fiber

The core idea
Wavelength division multiplexing sends multiple independent signals down one fiber, each on its own wavelength. The fiber count stays the same; the capacity multiplies. There are two mainstream variants, and they are chosen for different reasons.
CWDM — coarse wavelength division multiplexing
- Channel spacing: 20 nm
- Typical channel count: up to 18, spanning roughly 1270 nm to 1610 nm
- Light source: uncooled DFB lasers
- Cost: lower per channel, because uncooled lasers are cheaper and consume less power
- Reach: typically up to 80–120 km, but practical distances are often limited by the fact that CWDM channels are not compatible with standard erbium-doped fiber amplifiers (EDFAs)
DWDM — dense wavelength division multiplexing
- Channel spacing: 100 GHz (~0.8 nm) or 50 GHz (~0.4 nm)
- Typical channel count: 40 to 80+ in the C-band
- Light source: cooled, wavelength-stabilised lasers
- Cost: higher per channel, because the lasers must be temperature-stabilised and precisely tuned
- Reach: designed to work with EDFA amplification, which is what makes multi-hundred-kilometre spans feasible
The decision table
| | CWDM | DWDM | |---|---|---| | Spacing | 20 nm | 100 / 50 GHz | | Channels | Up to 18 | 40–80+ | | Laser | Uncooled | Cooled | | Per-channel cost | Lower | Higher | | Amplifier compatible | No (standard EDFA band) | Yes | | Typical reach | 40–80 km | 80 km to several hundred km | | Best fit | Metro access, capacity on a budget | Long-haul, high channel count, amplified spans |
How to choose
Two questions usually settle it:
- Do you need amplification? If the span needs an EDFA, DWDM is the answer. CWDM channels fall outside the standard amplification band.
- How many channels do you actually need? If the answer is under a dozen and the distance is inside 80 km, CWDM delivers the same result at materially lower cost per channel.
A common pattern is CWDM in the metro access layer and DWDM in the core, with an OADM or ROADM handoff between them.
What to plan before ordering
- The full channel plan, not just today's channels — the filter and mux/demux units are sized once.
- Insertion loss for every passive component, including patch panels and OADMs. Long-reach WDM links fail on optical budget far more often than on module quality.
- Optical testing on the link before commissioning. This is standard practice and worth insisting on.
Canjin Technology supplies CWDM and DWDM optics from 1.25G SFP to 10G SFP+, in 40 km, 80 km and 120 km classes with full channel listings by part number.
Связанная продукция и решения
Оптические трансиверы SFP (155M – 2.5G)Пришлите BOM — остальное мы посчитаем
Пришлите список моделей, целевые скорости или расстояния. Наши инженеры ответят подобранными партномерами, сроками и ценой.


